5.3 SM CIRIUS AO CABLING INSTALLATION
5.3.1 INSTALLING GBE ELECTRICAL FOR TRAFFIC& POWER
Prerequisites
See below the prerequisites before starting S-FTP cable installation to SM CIRIUS AO:
Availability of 1 x S-FTP Cable terminated to RJ-45 jack (see page
39
).
S-FTP Cable length restrictions, as follows:
o
Due to Electrical ETH limitation the S-FTP cable length between SM CIRIUS AO up to
network equipment should not exceed 100 m.
o
Due to Power limitation the S-FTP cable length between SM CIRIUS AO up to PoE OUT
receptacle should not exceed the following distances:
Num. of
S-FTP
Cables
One
Cable
Two
Cables
(Power in parallel
Voltage supply at PoE input
-40.5 to -60 V
-40.5 to -60 V
-45.5 to -60 V
Freq. Band
8 GHz
50 m
100 m
200(*) m
Freq. Band
11 GHz
75 m
150 m(*)
200(*) m
Freq. Band
13-38 GHz
100 m
200 m(*)
-
Tools
See below the required tools for connecting Ethernet (S-FTP) cables into SM CIRIUS for traffic,
inband management & power
(see list in chapter
Installation Tools
, on page
12
):
Item 1
Item 2 (AZ-2.5)
Item 7 (24 mm)
Summary of Contents for SM Cirius AO
Page 1: ...SM Cirius AO Point to point microwave IP radio with POE Installation Manual ...
Page 3: ...7 2 APPENDIX B RMA RETURN MATERIAL AUTHORIZATION FORM 83 ...
Page 6: ...SM Cirius AO Vertical view ...
Page 24: ...Cabling implementation for traffic power ...
Page 26: ...Cabling implementation for outband power ...
Page 29: ...Cabling implementation for traffic outband power ...
Page 63: ...Item Description A Thread adaptor B Cable holder C Seal 1 D Spacer ring E Cap ...