Procedure
To terminate each S-FTP cable, follow the steps below:
Step
Action
1
Strip the cable jacket 30 - 40 mm taking care not to injure the insulation of the
conductors or the shield of the cable.
2
Fold the outside shield and drain wire back over the jacket.
3
Trim the foil up to 2 mm max from the jacket end.
4
Slide the plug shield over the cable jacket and cable shield taking care not to injure the cable
shield. Do not slide the plug shield past the folded back end of the cable shield.
5
While firmly holding the cable jacket next to the stripped end, untwist the pairs as much as
possible.