– 13 –
4-5-2. X-ON/X-OFF mode
This mode is accessed when DIP switch 1-3 is set to OFF.
Immediately after power on (provided that no error occurs), the printer informs
the host that it is ready to receive data by outputting the X-ON signal (control code
DC1; value = 11H) over the TXD line. If necessary the printer repeats the signal
every three seconds until the host begins sending text data over the RXD line.
When the printer’s remaining buffer space falls to 256 bytes or less, the printer
begins to output X-OFF signals (DC3, 13H) over the TXD line. The host
responds by halting the data transfer. Note that the printer remains capable of
receiving data until the buffer becomes full.
Available buffer space increases as the printer prints the buffered data. When the
printer has cleared all but the last 256 bytes of data, it again outputs the X-ON
signal.
TXD
RXD
ON
OFF
X–ON
X–OFF
X–OFF X–ON
X–OFF
X–OFF
X–OFF
X–ON
X–OFF
Printing
PAPER OUT
signal
ON LINE
indicator
Data
Data
Data
Paper out
Power ON
Load paper and press
the ON LINE switch.
Data buffer full
Nearly full
Nearly empty
Empty
256 bytes
Printer outputs
X-OFF.
256 bytes
remaining
Pinter outputs
X-ON.
SERIAL
Summary of Contents for TSP400 Series
Page 1: ...Thermal Printer TSP400 Series TUP400 Programmer s Manual...
Page 2: ......
Page 103: ...100 Page Mode Character type Small size or standard...
Page 104: ...101 Page Mode Character type Boldface...
Page 105: ...102 Page Mode International Character Set...
Page 106: ...103 Line Mode...
Page 107: ...104 Line Mode Character table Normal...
Page 108: ...105 Line Mode Character table katakana...
Page 109: ...106 Line Mode Character table IBM...
Page 110: ...107 Line Mode International Character Set...
Page 135: ......