© 2021 Staheli West
164
Test 1002: Spark Test
1
3
5
2
4
6
Disconnect the safety relay and the low fire relay.
Remove the bulkhead. Connect both spark coil wires
together with the bulkhead and place the burner gun
assembly on the deck as shown.
Start the machine like normal.
Remove the burner gun assembly.
When the machine gets to the “Spark Ignition” phase,
sparking should occur between the electrodes on the
burner gun for 4 seconds. Make sure it is sparking on
the tips of the electrodes and sparking inside the tube.
If there is no spark, see fault 1005 for causes.
See Test 1003 for electrode gap settings.
Replace the burner hood.
Safety
Low Fire
Summary of Contents for DewPoint 331
Page 213: ... 2021 Staheli West 204 Notes ...