Faults
Fault 1257: Steam Pressure Sensor Reading High (over 18 PSI)
This can be caused by a frozen sensor due to improper machine winterization.
Causes
Troubleshooting
Fixes
• Faulty steam pressure sensor.
• Replace steam pressure sensor.
Fault 1258: Baler Chamber Pressure Sensor Not Connected
Indicates ≥4mA is not present on the signal wire.
Causes
Troubleshooting
Fixes
• Sensor disconnected.
• Connect sensor.
• Faulty sensor.
• Swap with compatible sensor
(See sensor page).
• Replace sensor.
• Faulty wiring.
• Inspect the wiring for ground,
continuity, and proper voltage.
• Repair/Replace wiring.
Fault 1259: Baler Chamber Pressure Sensor Amperage High
Indicates >22mA is present on the signal wire for 5 seconds.
Causes
Troubleshooting
Fixes
• Faulty sensor.
• Swap with compatible sensor
(See sensor page).
• Replace sensor.
• Faulty wiring.
• Inspect the wiring for ground,
continuity, and proper voltage.
• Repair/Replace wiring.