Spike Systems: PBG System Family Installation
62
release valve in the clockwise direction will allow the gate to go down manually. Ensure
that this valve is turned in the opposite direction (counter-‐clockwise) once system
operation has been restored.
Figure 69 – Manual Gate Lowering in Case of Power Loss or Other Unusual Event
4.3 Important Hydraulic Power Unit (Pump) Information
4.3.1 Observations and Recommendations
When connecting AC current, please observe the indicated rotation of the electric
motor. Running the motor in the opposite direction of the indication will result in shaft
seal damage. All electric connections should be done according to local standards.
Failure to comply with local standards
and use of non-‐certified components may result
in injury
. All hydraulic connections should be made, and the proper fluid should be
present in the reservoir before, running the Hydraulic pump.
4.3.2 Seal Kits and Components
To obtain a seal kit, the model number and serial number of the power pack is needed.
Most parts are available separately, however the pump is only replaced in whole and
separate trust-‐plates or loose shafts cannot be obtained. In order to ensure the quality
and performance of our product, all Hydraulic pumps are tested for performance at the
factory.
Summary of Contents for PBG Series
Page 8: ...Spike Systems PBG System Family Installation vi...
Page 22: ...Spike Systems PBG System Family Installation 14 INTENTIONALLY BLANK...
Page 56: ...Spike Systems PBG System Family Installation 48 Figure 54 Siemens PLC Wiring Scheme...
Page 68: ......
Page 82: ...Spike Systems PBG System Family Installation 74...
Page 84: ......
Page 90: ...Spike Systems PBG System Family Installation 82...
Page 91: ...Spike Systems PBG System Family Installation 83...
Page 92: ...Spike Systems PBG System Family Installation 84...
Page 93: ...Spike Systems PBG System Family Installation 85...
Page 94: ...Spike Systems PBG System Family Installation 86...