75
-
○
3
Sn-04=10 XX Full-range DC injection braking stop
DC injection braking time differs by the output frequency when stop command is
input as shown below.
○
4
Sn-04=11 XX Coasting to a Stop (timer function provided)
Once stop command is input, run command is disregarded during T
1
time.
CUTOFF OF
INVERTER
OUTPUT (Cn-40 setting value)
CLOSED
OPEN
RUN COMMAND
OUTPUT FREQUENCY
DC INJECTION
BRAKING TIME
Cn-12×10
10% SPEED 100% SPEED
OUTPUT FREQUENCY WHEN STOP
REFERENCE IS INPUT
DC INJECTION BRAKING
TIME AT STOP (Cn-12)
DC INJECTION
BRAKING TIME
T
1
TIME
WHEN STOP REFERENCE
IS INPUT, INVERTER
OUTPUT IS CUTOFF
CLOSED
OPEN
RUN COMMAND
OUTPUT FREQUENCY
CLOSED
100% SPEED
OUTPUT FREQUENCY WHEN
STOP REFERENCE IS INPUT
T
1
TIME
DECELERATION TIME
Summary of Contents for 7300PA series
Page 6: ... 4 PART I INSTALLATION MANUAL ...