107
-
2.6 Monitoring Parameters H n -
□ □
The inverter input/output interface status can be monitored under the PRGM mode
by Hn-
□□
parameter.
Hn-
□□
parameter will toggle display with low voltage protection alarm (UV) if the
UV alarm occurred.
Parameter
No.
Name
LCD Display
(English)
Unit Descriptions
Hn-01
Main Circuit DC Voltage
Hn-01=622.0V
DC Voltage
0.1V Display DC voltage of inverter main circuit
Hn-02
Input Terminal Status
Hn-02=00000000
I/P Term. Status
-
0 0 0 0 0 0 0 0
0
:
OPEN
1
:
CLOSE
Input terminal
○
1
Input terminal
○
2
Input terminal
○
3
Input terminal
○
4
Input terminal
○
5
Input terminal
○
6
Input terminal
○
7
Input terminal
○
8
Hn-03
Output Terminal Status
Hn-03=00000000
O/P Term. Status
-
0 0 0 0 0 0 0 0
0
:
OPEN
1
:
CLOSE
Relay Contact
R2A-R2C
Opto-contact
D01-DCOM
Opto-contact
R1A-R1C
Reversed
Reversed
Reversed
Reversed
Reversed
Hn-04
Option card code
Hn-04=0
None Opt. Card
1
0
:
None of option card is installed
1
:
PA-M (MODBUS) card is installed.
2~5
:
Reserved
6
:
PA-P (PROFIBUS) card is installed .
7
:
Reserved
8
:
PA-PID card is installed.
Hn-05
U phase current (IU)
conversion value
Hn-05=2.50V
IU current
Hn-06
W phase current (IW)
conversion value
Hn-06=2.50V
IW current
Hn-07
3 phase rectify current
(DIAC) conversion value
Hn-07=1.00V
DIAC current
Hn-08
ADC Reference Volt.
conversion value
Hn-08=2.50V
ADCHK Voltage
0.01V
Range
:
0.00V ~ 5.00V
Hn-05, Hn-06 can be used to check DCCT
function.
Hn-07, Hn-08 can be used to check ADC
function in the control board.
Troubleshooting used.