50
-
Function
Parameter
No.
Name
LCD Display (English) Setting Range
Setting
Unit
Factory
Setting
Ref.
Page
Cn-26
Overtorque Detection
Level
Cn-26=160%
Over Tq. Det. Level
30
〜
200%
1% 160%
OVER-
Torque
Detection
Cn-27
Overtorque Detection
Time
Cn-27=00.1s
Over Tq. Det. Time
0.0
〜
25.5s
0.1s 0.1s
56
Cn-28
Stall Prevention Level
During Acceleration
Cn-28=150%
ACC. Stall
30
〜
200%
1% 150% 56
Cn-29 Not
used
Cn-29=000
Reserved
00
〜
000
-
-
-
Stall
Prevention
Cn-30
Stall Prevention Level
During Running
Cn-30=130%
Running Stall
30
〜
200%
1% 130% 56
Communic
-ation Fault
Cn-31
Communication Fault
Detection Time
Cn-31=01.0s
Comm. Flt. Det. Time
0.1
〜
25.5s
0.1s 1s 57
Cn-32
Freguency Detection
1 Level
Cn-32=000.0Hz
Freg.Det. 1 Level
0.0~180.0Hz 0.1Hz 0.0Hz 57
Freguency
Detection
Cn-33
Freguency Detection
2 Level
Cn-33=000.0Hz
Freg.Det. 2 Level
0.0~180.0Hz 0.1Hz 0.0Hz 57
Cn-34 Not
used
Cn-34=0
Reserved
0
〜
0
-
-
-
-
Cn-35 Not
used
Cn-35=0.0
Reserved
0.0
〜
0.0
-
-
-
Fault Retry
Cn-36
Number of Auto
Reatart Attempt
Cn-36=00
Retry Time
0
〜
10
1 0
58
63
Ride-thru
Time
Cn-37
Power Loss Ride-thru
Time
Cn-37=2.0s
Ride-thru Time
0
〜
2.0s
0.1s 2.0s*
4
58
Cn-38
Speed Search
Detection Level
Cn-38=150%
SP_Search Level
0
〜
200%
1% 150%
Cn-39
Speed Search Time
Cn-39=02.0s
SP_Search Time
0.1
〜
25.5s
0.1s 2.0s
Cn-40
Min. Baseblock Time
Cn-40=1.0s
Min. B.B. Time
0.5
〜
5.0s
0.1s 1.0s*
4
Cn-41
V/F Curve in Speed
Search
Cn-41=100%
SP_Search V/F Gain
10
〜
100%
1% 100%
Speed
Search
Control
Cn-42
Voltage Recovery
Time
Cn-42=0.3s
Voltage Recovery Time
0.1
〜
5.0s
0.1s 0.3s
59
Cn-43
PID Integral Upper
Bound
Cn-43=100%
PID I-Upper
0
〜
109%
1% 100%
PID
Control
Cn-44
PID Primary Delay
Time Constant
Cn-44=0.0s
PID Filter
0.0
〜
2.5s
0.1s 0.0s
60
Cn-45
Energy-Saving Volt.
Upper Limit (60Hz)
Cn-45=120%
Hi_Spd. Sav V_Upper
0
〜
120%
1% 120%
Cn-46
Energy-Saving Volt.
Upper Limit (6Hz)
Cn-46=16%
Lo_Spd. Sav V_Upper
0
〜
25%
1% 16%
Cn-47
Energy-Saving Volt.
Lower Limit (60Hz)
Cn-47=050%
Hi_Spd. Sav V_Lower
0
〜
100%
1% 50%
Energy-
Saving
Voltage
Limit
Cn-48
Energy-Saving Volt.
Lower Limit (6Hz)
Cn-48=12%
Lo_Spd. Sav V_Lower
0
〜
25%
1% 12%
60
Summary of Contents for 7300PA series
Page 6: ... 4 PART I INSTALLATION MANUAL ...
Page 35: ... 33 PART II OPERATION MANUAL ...