66
-
Function
Parameter
No.
Name
LCD Display
(English)
Description
Factory
Setting
Ref.
Page
Sn-12
Protective
Characteristic
Selection 3 (External
Fault signal function)
Sn-12=0100
External Fault
- - -0
:
External fault input (terminal
○
3
):
NO-contact input
- - -1
:
External fault input: NC-contact input
- -0 -
:
External fault signal: always detected
- -1 -
:
External fault signal: detected during
running only
00- -
:
External fault detected: Ramp to a
stop (major fault) by Bn-02 set
value
01- -
:
External fault detected: Coasting to
stop (major fault)
10- -
:
External fault detected: Ramp to a
stop (major fault) by Bn-04 set
value
11- -
:
External fault detected: opeation to
continue (major fault)
0100 83
Sn-13
Protective
Characteristic
Selection 4 (phase
lose protection and
cooling fan ON/OFF
control)
Sn-13=0000
Phase Lose & fan ON/OFF
- - -0
:
Input phase loss protection function
ineffctive
- - -1
:
Input phase loss protection function
effctive
- -0 -
:
Output phase loss protection function
ineffctive
- -1 -
:
Output phase loss protection function
effctive
- 0- -
:
Cooling fan run while inverter power
ON
- 1- -
:
Cooling fan run while heat sink
temperature higher then 50
℃
0000
83
84
Protective
Characteri-
stic Select
Sn-14
Protective
Characteristic
Selection 5
(Electronic thermal
overload protection)
Sn-14=0000
Over Load Select
- - -0
:
Motor overload (OL1) protection
effective
- - -1
:
Motor overload (OL1) protection
ineffective
- -0 -
:
Motor overload protection: standard
motor
- -1 -
:
Motor overload protection: Inverter
duty motor
- 0- -
:
Motor overload protection time
constants are standard time (8
minutes)
- 1- -
:
Motor overload protection time
constants are short-time (5 minutes)
0000 84
Sn-15
Terminal
○
5
Function
Sn-15=03
Term.5 Function
00~66
Terminal
○
5
(factory preset for
multi-step speed reference 1)
03
Sn-16
Terminal
○
6
Function
Sn-16=04
Term.6 Function
00~66
Terminal
○
6
(factory preset for
multi-step speed reference 2)
04
Sn-17
Terminal
○
7
Function
Sn-17=06
Term.7 Function
00~66
Terminal
○
7
(factory preset for
jog frequency reference)
06
Sn-18
Terminal
○
8
Function
Sn-18=08
Term.8 Function
00~66
Terminal
○
8
(factory preset for
external baseblock by NO contact
input)
08
85
~
94
Sn-19
Terminal AUX
Function
Sn-19=00
Multi-Fct Input
00~0C
Terminal AUX (factory preset for
auxiliary frequency command)
00
95
96
Sn-20
Terminal R2A-R2C
Function
Sn-20=00
Term. R2A Function
00~0F
Terminal R2A-R2C (factory
preset for running)
00
Sn-21
Terminal D01
Function
Sn-21=01
Term. D01 Function
00~0F
Terminal D01 (factory preset for
zero speed)
01
Multi-Function
Select
Sn-22
Terminal R1A
Function
Sn-22=02
Term. R1A Function
00~0F
Terminal R1A (factory preset for
Agreed frequency)
02
97
~
100