1.2 DRIVE mode and PRGM mode displayed contents
*1
:
When the inverter is put into operation,
the inverter system immediately enters into
DRIVE mode. Press the
PRGM
DRIVE
key,
the system will switch into PRGM mode.
*2
:
If the fault occurred before power
supply was turned off, the fault contents
are displayed when power ON.
Fault occurrence order and display are
provided by or key.
Un fault : n =1~4,the fault occurrence
Order, fault :the fault contents,
please refer to page 111~114,the fault display.
*3
:
If no fault occurred before power supply was turned off , display the monitored data
according to the Bn-10 setting
*4
:
This block will be by passed if no fault occurred before power supply was turned off or a
fault occurs and was reset by
RESET
*5
:
When in the DRIVE mode, press the
DSPL
key and
RESET
key, the setting values of Sn-
and Cn-
□□
will only be displayed for monitoring but not for changing or setting.
Power on
PRGM mode
DRIVE mode
PRGM
DRIVE
*1
DSPL
An-
□□
monitor
/
set
DSPL
Bn-
□□
monitor
/
set
DSPL
Sn-
□□
monitor
/
set
DSPL
Cn-
□□
monitor
/
set
DSPL
Hn-
□□
monitor
/
set
When faults
Occurred before
power supply
was turned off
*2
DSPL
Frequency reference
DSPL
Un-
□□
monitor
DSPL
An-
□□
monitor
/
set
DSPL
Bn-
□□
monitor
/
set
DSPL
Sn-
□□
monitor
DSPL
Cn-
□□
monitor
*4
DSPL
*5
+
RESET
DSPL
Output Frequency
Output Current
PID detected value
Display of faults which
occurred before power supply
was turned off
*3
∧
∨