Field
Setting
Address
If master server, enter the fixed IP address or hostname
for the backup Spectralink IP-DECT Server 6500/Spec-
tralink Virtual IP-DECT Server One.
If backup server, enter the fixed IP address or hostname
for the master Spectralink IP-DECT Server 6500/Spec-
tralink Virtual IP-DECT Server One.
Redundancy Configuration - System identification
UUID (Optional)
The UUID (unique ID) of the redundant system. This
must be the same for master server and backup server
for replication to be performed. The master server auto-
matically generates the UUID.
Note
: When reset on the master server, the UUID is auto-
matically generated, and when reset on the backup
server, it is retrieved from the master server. The UUID
must be reset when a master Spectralink IP-DECT/Vir-
tual IP-DECT Server is changed to a backup Spectralink
IP-DECT/Virtual IP-DECT Server, or when a backup
Spectralink IP-DECT/Virtual IP-DECT Server is moved
to another solution.
Reset UUID (Optional)
If enabled, the UUID is reset if the UUID of the master
server and backup server is not matching.
Redundancy Configuration - Settings
Failover time(sec)
Enter value for failover time.
Failure time is the time in seconds from the Spectralink
IP-DECT/Virtual IP-DECT Server detects a failure, until
it initiates a failover operation and cause the other peer to
take over.
Default value: 15 sec
For more information about failure time, see
.