![Spectracom GSG-5 series User Manual With Scpi Manual Download Page 99](http://html1.mh-extra.com/html/spectracom/gsg-5-series/gsg-5-series_user-manual-with-scpi-manual_1343630099.webp)
1.
Navigate to
Options > Transmit Power
.
2.
Adjust the GPS L1C/A band
Ref. power
. The power is specified in
dBm
. The supported
range is: Max. -65 dBm … Min. -160 dBm.
3.
Select
Signals power configuration
to open the corresponding menu.
4.
Select the desired constellation, and adjust the power for each signal type supported by
this constellation.
Note:
When changing the power setting for a signal type, the Reference
Power (absolute power level of GPS L1 C/A) and Relative Power offsets
for all the remaining signal types will remain unchanged.
Figure 3-25:
Signals power configuration menu
Use the
format
key to switch between the absolute or relative mode of displaying/editing
power. When the
Absolute Power
mode is active and
Reference Power
is changed, the
Relative
Power
offsets will stay unchanged, so that absolute powers will be “shifted” together with the
Reference Power
.
Default Power Configurations
Signal name
Orbit type name
Absolute power
(dBm)
Relative power
(dBm)
GPSL1CA (reference)
-128.5
0
GPSL1P
-131.5
-3
GPSL2P
-131.5
-3
GPSL2C
-128.5
0
GPSL5
-127
+1.5
3.6 "Options" Menu
CHAPTER
3
•
User Manual GSG-5/6 Series
Rev.
26
83
Summary of Contents for GSG-5 series
Page 2: ......
Page 4: ...Blank page II User Manual GSG 5 6 Series...
Page 116: ...BLANK PAGE 3 6 Options Menu 100 CHAPTER 3 User Manual GSG 5 6 Series Rev 26...
Page 182: ...BLANK PAGE 4 9 Studioview Tasks 166 CHAPTER 4 User Manual GSG 5 6 Series Rev 26...
Page 368: ...BLANK PAGE 6 7 Revision History SCPI Guide 352 CHAPTER 6 User Manual GSG 5 6 Series Rev 26...