5.
Issue the RLM command(s), using the Console e.g.:
write SOUR:SCEN:RLM 0,8,711888,141509,1025,65536
6.
The submission should be confirmed:
OK [no errors]
.
7.
View the received message on the receiver, see the following example:
For automated testing e.g., when integrating GSG into a larger test system, a SCPI program
can be written. In this case, StudioView would not be needed.
5.9
Galileo E6-B/C Signal
GSG's optional Galileo E6-B/C signals are pseudo-signals for the Galileo Commercial Service
(CS). Both signals are sent unencoded: A secondary code (pilot tone) is sent on the E6-C fre
quency band, with no data. On the E6-B band dummy data is sent at 448 bps.
To utilize this optional functionality a GSG- 6 unit with an available frequency band is
required, as well as the
OPT-GAL
and
OPT-L6
option packages.
5.10
Default Settings
The factory settings are considered default settings. You can restore these settings at any time
by navigating to
Options
>
Reset to factory defaults
.
The default settings are:
Transmit power
: -125 dBm
External attenuation
: 0 dB
Interface type
: Ethernet
Obtain IP automatically
: Yes
GPIB address
: 01
5.9 Galileo E6-B/C Signal
CHAPTER
5
•
User Manual GSG-5/6 Series
Rev.
26
179
Summary of Contents for GSG-5 series
Page 2: ......
Page 4: ...Blank page II User Manual GSG 5 6 Series...