6.3.6
STATus: Subsystem Commands
6.3.6.1
STATus:OPERation:CONDition?
Function
Reads out the contents of the operation status condition register. This register reflects the state of
the GSG operation.
Command Syntax
STATus:OPERation:CONDition?
Returned Format
<Decimal data> = the sum (between 0 and 97) of all bits that are true. See table below:
Bit Weight
Condition
6
64
Waiting for bus arming
5
32
Waiting for triggering and/or external arming
0
1
Calibrating
6.3.6.2
STATus:OPERation:ENABle
Function
Enables operation status reporting by setting the enable bits of the Operation Status Enable
register.
This register contains a mask value for the bits to be enabled in the Operation Status Event
register. A bit that is set True in the enable register enables the corresponding bit in the status
register.
An enabled bit will set bit #7, OPR (Operation Status Bit), in the Status Byte Register if the
enabled event occurs.
Command Syntax
STATus:OPERation:ENABle <Decimal data>
Parameters
<decimal data> = the sum (between 0 and 96) of all bits that are true. See table below:
308
CHAPTER
6
•
User Manual GSG-5/6 Series
Rev.
26
6.3 Command Reference
Summary of Contents for GSG-5 series
Page 2: ......
Page 4: ...Blank page II User Manual GSG 5 6 Series...
Page 116: ...BLANK PAGE 3 6 Options Menu 100 CHAPTER 3 User Manual GSG 5 6 Series Rev 26...
Page 182: ...BLANK PAGE 4 9 Studioview Tasks 166 CHAPTER 4 User Manual GSG 5 6 Series Rev 26...
Page 368: ...BLANK PAGE 6 7 Revision History SCPI Guide 352 CHAPTER 6 User Manual GSG 5 6 Series Rev 26...