4-15
CSM-200
N20
M20
Allen wrench (10 mm)
Bubble
The bubble in the level must stay in the
center of the internal gauge lines.
Caster
[A]
[B]
[C]
Height from the floor level is 275 mm.
3.
Check that height of point [A] is 275 mm above the floor. If height of point [A] is not 275 mm, adjust
height as follows. Loosen the four nuts of the respective casters with open-end wrench. Adjust height
of the respective casters with hexagon Allen wrench (diagonal size: 10 mm). (One full clockwise
rotation of a caster by 360
d
raises the console by 2.5 mm. Counter-clockwise rotation of a caster by
360
d
lowers the console by 2.5 mm.)
4.
Place a level on the portions [B] and [C], and check that the basic storage system is level. If the basic
storage system is not level, adjust height of the casters until it is level.)