Electrical documentation
© Solarbayer GmbH [210105]
61
X1 – 230 V AC – Power line – Phönix RM 5,08
Pin
Signal
Function
1
L
IN
Mains voltage
2
L
STL
Mains voltage STL
3
N
Neutral line
4
PE
Ground conductor
5
L
exhaust blower
Mains voltage exhaust blower
6
N
Neutral line
7
PE
Ground conductor
8
L
WTR
Mains voltage WTR
9
N
Neutral line
10
PE
Ground conductor
X2 – Digital und analog inputs – Phönix RM 3,5
Pin
Signal
Function
1
AI1
Analog input boiler temperature
2
AGND
AGND
3
AI2
Analog input exhaust gas temperature
4
AGND
AGND
5
+24V
+24V supply voltage
6
DI1
Digital input: filling chamber door
X3 – CAN-Bus: Interface to modules – Phönix RM 3,5
Pin
Signal
Function
1
–
CAN A
2
–
CAN B
3
–
GND
X5 – Digital input: speed feedback – Phönix RM 3,5
Pin
Signal
Function
1
+24V
Supply v24V DC digital input
2
DI1
Counter input: speed feedback
3
GND
GND