Description of menu navigation and setting values
56
© Solarbayer GmbH [210205]
12
DESCRIPTION OF MENU NAVIGATION AND SETTING VALUES
12.1
Main menu
12.1.1
Structure
The structure of the display consists of the menu (parameters, status, unit test inputs and unit test outputs),
the boiler status and the error messages.
This page is automatically loaded after you have switched on the system with the main switch (on the back).
From here you can easily navigate through the settings.
12.1.2
Display
Boiler status:
1 … Unit Off
4 … Control phase
7 … Re-heating
2 … Burning phase
5 … Ready
8 … Chimney sweeper
3 … High running phase
6 … New start-up
By pressing the button:
„On/Off“:
Press and hold: the system is switched on or off.
Press shortly: the error check is carried out.
„X1“:
Changes to the displayed menu / confirm change
„X2“:
Scroll up / increase value
„X3“:
Scroll down / decrease value
„X4“:
"ENTER" - button / Cancel change / When the "
" symbol is displayed, the status
changes to chimney sweep mode
X1
X2
X3
X4
4
11
S
P01
P02
P03
P21
***
83
127
90
°C
°C
Actual boiler
status
Fault
message
Active menu item
Function of the X - buttons
On/Off – button