Description of menu navigation and setting values
58
© Solarbayer GmbH [210205]
12.3
Specialist level (111)
Specialist level
Statusmenü (S)
S1 Boiler temperature
S8
O
2
-actual value
S15 Heat exchanger cleaning (WTR)
S2 Return flow temperautre
S9
Lambda heating
S16 WTR-monitoring
S3 Buffer-top
S10 Primary air
S17 Sum error
S4 Buffer-bottom
S11 Secundary air
S18 Hardware-Version HZS621
S5 Exhaust gas temperautre S12 Return pump
S19 Software-Version HZS621
S6 Fan power
S13 Return mixer open
S20 Hardware-Version HZS631
S7 Fan rotation speed
S14 Return mixer close
S21 Software-Version HZS631
Parametermenü (P)
P01 Code input
P03 Boiler temp. setting
(83°C)
P07 Max. new start-up time
(10min)
P02 Boiler temp. max
(90°C)
P06 Igniter detection
(120°C)
P21 Contrast display
(127)
Ausgänge - Aggregattest (A)
A01 Return pump(O/X)
A04
Fan power (%)
A07 Secundary air(%)
A02 Return mixer-open* (O/X) A05
Lambda heating
A08 Heat exchanger cleaning(WTR)
A03 Return mixer-close* (O/X) A06
Primary air (%)
A09 Sum error
*
To test the return mixer, the signals (0/X) must always be controlled in the opposite direction!
Eingänge (E)
E01 STL
E03 Fan rotation speed
E06 WTR-monitoring
E02 Door contact
E05 O
2
-actual valve
Code i (P01):
The keys X1, X2 and X3 stand respectively
for the 100s digit, 10s digit and 1s digit!
Code of the specialist level =
111
For the start-up, the outputs (A) must be
checked. For this purpose, the boiler
MUST
be in status
1 (Off)
(see p.56)! Code level
resets automatically after a few minutes!
1
+100
P01*
P02
P03
P21
***
83
127
90
°C
°C
+
10
+1
Boiler
on
S
P
Status
menu
Parameter
menu
A
S01
…
S21
P01
…
P21
Outputs
menu
E
Inputs
menu
A01
…
A09
E01
…
E05