C
ONFIGURING
THE
S
WITCH
3-46
CLI
– Enter the IP address of at least one SMTP server, set the syslog
severity level to trigger an email message, and specify the switch (source)
and up to five recipient (destination) email addresses. Enable SMTP with
the
logging sendmail
command to complete the configuration. Use the
show logging sendmail
command to display the current SMTP
configuration.
Renumbering the Stack
If the units are no longer numbered sequentially after several topology
changes or failures, you can reset the unit numbers using the
“Renumbering” command. Just remember to save the new configuration
settings to a startup configuration file prior to powering off the stack
Master.
Console(config)#logging sendmail host 192.168.1.4
4-65
Console(config)#logging sendmail level 3
4-66
Console(config)#logging sendmail source-email
4-67
Console(config)#logging sendmail destination-email
4-68
Console(config)#logging sendmail
4-68
Console(config)#exit
Console#show logging sendmail
4-69
SMTP servers
-----------------------------------------------
1. 192.168.1.4
SMTP minimum severity level: 4
SMTP destination email addresses
-----------------------------------------------
1. [email protected]
SMTP source email address: [email protected]
SMTP status: Enabled
Console#