B
ASIC
C
ONFIGURATION
3-17
CLI
– Specify the hostname, location and contact information.
Displaying Switch Hardware/Software Versions
Use the Switch Information page to display hardware/firmware version
numbers for the main board and management software, as well as the
power status of the system.
Field Attributes
Main Board
•
Serial Number
– The serial number of the switch.
•
Number of Ports
– Number of built-in ports.
•
Hardware Version
– Hardware version of the main board.
Console(config)#hostname R&D 5
4-34
Console(config)#snmp-server location WC 9
4-143
Console(config)#snmp-server contact Ted
4-142
Console(config)#exit
Console#show system
4-80
System description: SMC8724ML3 L3 GE Switch
System OID string: 1.3.6.1.4.1.202.20.45
System information
System Up time: 0 days, 1 hours, 28 minutes, and 0.51
seconds
System Name: R&D 5
System Location: WC 9
System Contact: Ted
MAC address (unit1): 00-30-F1-D4-73-A0
Web server: enabled
Web server port: 80
Web secure server: enabled
Web secure server port: 443
Telnet server: enable
Telnet server port: 23
Authentication login: local RADIUS none
Jumbo Frame: Disabled
POST result
UART Loopback Test ........... PASS
DRAM Test .................... PASS
Timer Test ................... PASS
PCI Device 1 Test ............ PASS
I2C Bus Initialization ....... PASS
Switch Int Loopback Test ..... PASS
Crossbar Int Loopback Test ... PASS
Fan Speed Test ............... PASS
Done All Pass.
Console#
Summary of Contents for 8724ML3 - annexe 1
Page 2: ......
Page 26: ...TABLE OF CONTENTS xxvi ...
Page 64: ...MANAGING SYSTEM FILES 2 18 ...
Page 400: ...CONFIGURING THE SWITCH 3 336 ...
Page 798: ...SOFTWARE SPECIFICATIONS A 6 ...
Page 802: ...TROUBLESHOOTING B 4 ...
Page 812: ...GLOSSARY Glossary 10 ...
Page 818: ...INDEX Index 6 ...
Page 819: ......