C
ONFIGURING
THE
S
WITCH
3-40
CLI
– Enter the IP address of at least one SMTP server, set the syslog
severity level to trigger an email message, and specify the switch (source)
and up to five recipient (destination) email addresses. Enable SMTP with
the
logging sendmail
command to complete the configuration. Use the
show logging sendmail
command to display the current SMTP
configuration.
Renumbering the Stack
If the units are no longer numbered sequentially after several topology
changes or failures, you can reset the unit numbers using the
“Renumbering” command. Just remember to save the new configuration
settings to a startup configuration file prior to powering off the stack
Master.
Command Usage
•
The startup configuration file maps configuration settings to each
switch in the stack based on the unit identification number. You should
Console(config)#logging sendmail host 192.168.1.4
4-66
Console(config)#logging sendmail level 4
4-67
Console(config)#logging sendmail source-email
4-67
Console(config)#logging sendmail destination-email
4-68
Console(config)#logging sendmail
4-69
Console(config)#exit
Console#show logging sendmail
4-69
SMTP servers
-----------------------------------------------
1. 192.168.1.4
2. 192.168.1.5
SMTP minimum severity level: 4
SMTP destination email addresses
-----------------------------------------------
1. [email protected]
SMTP source email address: [email protected]
SMTP status: Enabled
Console#
Summary of Contents for 8700S-130
Page 2: ......
Page 3: ......
Page 8: ...LIMITED WARRANTY iv ...
Page 56: ...INITIAL CONFIGURATION 2 18 ...
Page 189: ...PORT CONFIGURATION 3 133 Figure 3 61 Port Statistics continued ...
Page 566: ...COMMAND LINE INTERFACE 4 294 ...
Page 571: ...SOFTWARE SPECIFICATIONS A 5 Trap RFC 1215 UDP MIB RFC 2012 ...
Page 572: ...SOFTWARE SPECIFICATIONS A 6 ...
Page 576: ...TROUBLESHOOTING B 4 ...
Page 589: ......
Page 591: ...38 Tesla Irvine CA 92618 Phone 949 679 8000 ...
Page 592: ... 8 ...