C
OMMAND
L
INE
I
NTERFACE
4-70
Time Commands
The system clock can be dynamically set by polling a set of specified time
servers (NTP or SNTP). Maintaining an accurate time on the switch
enables the system log to record meaningful dates and times for event
entries. If the clock is not set, the switch will only record the time from the
factory default set at the last bootup.
sntp client
This command enables SNTP client requests for time synchronization
from NTP or SNTP time servers specified with the
sntp servers
command. Use the
no
form to disable SNTP client requests.
Syntax
[
no
]
sntp client
Default Setting
Disabled
Command Mode
Global Configuration
Table 4-22 Time Commands
Command
Function
Mode Page
sntp client
Accepts time from specified time servers
GC
4-70
sntp server
Specifies one or more time servers
GC
4-70
sntp poll
Sets the interval at which the client polls for
time
GC
4-72
show sntp
Shows current SNTP configuration settings
NE,
PE
4-73
clock timezone
Sets the time zone for the switch’s internal
clock
GC
4-73
calendar set
Sets the system date and time
PE
4-74
show calendar
Displays the current date and time setting
NE,
PE
4-75
Summary of Contents for 8700S-130
Page 2: ......
Page 3: ......
Page 8: ...LIMITED WARRANTY iv ...
Page 56: ...INITIAL CONFIGURATION 2 18 ...
Page 189: ...PORT CONFIGURATION 3 133 Figure 3 61 Port Statistics continued ...
Page 566: ...COMMAND LINE INTERFACE 4 294 ...
Page 571: ...SOFTWARE SPECIFICATIONS A 5 Trap RFC 1215 UDP MIB RFC 2012 ...
Page 572: ...SOFTWARE SPECIFICATIONS A 6 ...
Page 576: ...TROUBLESHOOTING B 4 ...
Page 589: ......
Page 591: ...38 Tesla Irvine CA 92618 Phone 949 679 8000 ...
Page 592: ... 8 ...