C
ONFIGURING
THE
S
WITCH
3-32
Web
– Click System, Line, Telnet. Specify the connection parameters for
Telnet access, then click Apply.
Figure 3-14 Configuring the Telnet Interface
CLI
– Enter Line Configuration mode for a virtual terminal, then specify
the connection parameters as required. To display the current virtual
terminal settings, use the
show line
command from the Normal Exec
level.
Console(config)#line vty
4-14
Console(config-line)#login local
4-15
Console(config-line)#password 0 secret
4-16
Console(config-line)#timeout login response 300
4-17
Console(config-line)#exec-timeout 600
4-18
Console(config-line)#password-thresh 3
4-19
Console(config-line)#end
Console#show line
4-24
Console configuration:
Password threshold: 5 times
Interactive timeout: Disabled
Login timeout: Disabled
Silent time: 60
Baudrate: auto
Databits: 8
Parity: none
Stopbits: 1
VTY configuration:
Password threshold: 3 times
Interactive timeout: 600 sec
Login timeout: 300 sec
Console#