S
PANNING
T
REE
A
LGORITHM
C
ONFIGURATION
3-155
•
Default –
- Ethernet – Half duplex: 2,000,000; full duplex: 1,000,000; trunk:
500,000
- Fast Ethernet – Half duplex: 200,000; full duplex: 100,000;
trunk: 50,000
- Gigabit Ethernet – Full duplex: 10,000; trunk: 5,000
•
Admin Link Type
– The link type attached to this interface.
- Point-to-Point – A connection to exactly one other bridge.
- Shared – A connection to two or more bridges.
- Auto – The switch automatically determines if the interface is attached
to a point-to-point link or to shared media. (This is the default
setting.)
•
Admin Edge Port
(Fast Forwarding) – You can enable this option if
an interface is attached to a LAN segment that is at the end of a bridged
LAN or to an end node. Since end nodes
cannot
cause forwarding
loops, they can pass directly through to the spanning tree forwarding
state. Specifying Edge Ports provides quicker convergence for devices
such as workstations or servers, retains the current forwarding
database to reduce the amount of frame flooding required to rebuild
address tables during reconfiguration events, does not cause the
spanning tree to initiate reconfiguration when the interface changes
state, and also overcomes other STA-related timeout problems.
However, remember that Edge Port should only be enabled for ports
connected to an end-node device. (Default: Disabled)
•
Migration
– If at any time the switch detects STP BPDUs, including
Configuration or Topology Change Notification BPDUs, it will
automatically set the selected interface to forced STA-compatible
mode. However, you can also use the Protocol Migration button to
manually re-check the appropriate BPDU format (RSTP or
STA-compatible) to send on the selected interfaces.
(Default: Disabled)
Summary of Contents for 8700S-130
Page 2: ......
Page 3: ......
Page 8: ...LIMITED WARRANTY iv ...
Page 56: ...INITIAL CONFIGURATION 2 18 ...
Page 189: ...PORT CONFIGURATION 3 133 Figure 3 61 Port Statistics continued ...
Page 566: ...COMMAND LINE INTERFACE 4 294 ...
Page 571: ...SOFTWARE SPECIFICATIONS A 5 Trap RFC 1215 UDP MIB RFC 2012 ...
Page 572: ...SOFTWARE SPECIFICATIONS A 6 ...
Page 576: ...TROUBLESHOOTING B 4 ...
Page 589: ......
Page 591: ...38 Tesla Irvine CA 92618 Phone 949 679 8000 ...
Page 592: ... 8 ...