44
ATCA-F140 Series Installation and Use (6806800M67S)
Introduction
Introduction
RJ-45 10/100/1000 BaseTx Ethernet Management port on the front panel for
P2020 QorIQ Integrated Processor
Broadcom BCM56334 managed switch device for the Base Channel (24 1G-SGMII
and four 10G-XAUI ports)
Two Fabric Channel 40G (QSFP+) uplink ports on the front panel
Multiple 1GbE SGMII and 10GbE XAUI ports routed to Zone 3 connectors for base
and fabric uplink channels on RTM
Two 40G ports routed to Zone 3 connectors for fabric uplink on RTM
Stratum 3 Telco clock option with master/slave sync and five inter-shelf sync
connectors on front panel along with two BITS/SSU front panel connectors
(specific to the ATCA-F140-TCLK3 blade)
One AMC bay for application processor support
IPMC functionality for the board management by the Shelf Management Controller
1.3
Standard Compliances
This blade, when installed in a compliant shelf, meets the following standards:
Table 1-1
Standard Compliances
Standard
Description
UL/CSA No. 60950-1
EN 60950-1
IEC 60950-1 CB Scheme
UL/CSA No. 60950-1
Legal safety requirements
ANSI T1.319-2002
NEBS GR-63-CORE
ANSI Fire Spread Criteria
AT&T Document ATT-TP-76200
Network Equipment Power, Grounding, Environmental, and
Physical Design Requirements
ETSI Acoustic Noise ETS 300 753
Class 3.1
ETSI acoustic noise requirements
ETSI Stationary Use: EN 300 019-
2-3 Class 3.1
ETSI stationary use requirements (temperature-controlled
locations)
ETSI Storage EN 300 019-2-1
Class 1.2
ETSI storage requirements in system level (not
temperature-controlled storage locations)
ETSI Transportation: EN 300 019-2-
2 Class 2.3
ETSI public transportation requirement on system level