Safety Notes
ATCA-F140 Series Installation and Use (6806800M67S)
23
The EMI radiation compliancy of the product has been qualified in a reference system.
Please note that the integrator needs to verify the EMI radiation compliancy of other
configurations/settings.
Switch Settings
Product Malfunction
Do not change settings of switches marked as
Reserved
. Switches marked
Reserved
might carry production-related functions and can cause the product to malfunction if their
setting is changed.
Check and change the setting of any switch not marked
Reserved
before installing the
product.
Product Damage
Check and change switch settings before you install the product.
Setting/resetting the switches during operation can cause damage to the product.
Use minimal force when pressing the reset switch. Too much force may damage the reset
switch.
RJ-45 Connector
System Damage
RJ-45 connectors on the front panel are either twisted-pair Ethernet (TPE) or E1/T1/J1
network interfaces. Connecting an E1/T1/J1 line to an Ethernet connector may damage
your system.
Make sure that TPE connectors near your working area are clearly marked as
network connectors.
Verify that the length of an electric cable connected to a TPE bushing does not
exceed 100 meters or approximately 328 feet.
Make sure the TPE bushing of the system is connected only to safety extra low
voltage circuits (SELV circuits).
If in doubt, ask your system administrator.
For more information, see the documentation of the respective product.