4 | Maintenance
Symptom
Cause
Solution
CommNode server
not assigned to task
services
If network tasks are
distributed via the
CommNode server,
you need to select this
in task services.
Select 'Network' »
'Task Manager'
Select the
CommNode server in
the Task services
section
Then transmit the
config files in the
'Communications
node' menu
CommNode server
not installed
The CommNode
needs to be installed
in certain setups:
– LSM Business
– LSM Basic with
Virtual Network
(VN)
Locking system with
Virtual Network (VN)
The config files must
be retransmitted to
the CommNode
server with
LSM.Basic.Databases
with VN configuration
to ensure that the
door monitoring
function is detected
Cam rotation is not
shown in LSM. Door
opening is shown
DM Cylinder
configured incorrectly
Configure lock dead
bolt logging. Check
box for event logging
and forwarding of lock
dead bolt events
DM Cylinder activated
in flipflop mode or
time switchover
DM Cylinder cannot
be operated in flipflop
mode or time switch
over. Change mode
and open and close
door, so that cylinder
returns to a defined
status