4.
Highlight 'Activate forwarding of events' in the 'Configuration'
section
5.
Click on 'Programme'
ð
Forwarding of events is now set up
Reset/replace
LockNode
If the DM Cylinder does not automatically forward status changes to
the door after configuration and initial operation, the LockNode may
be configured incorrectly. If this is the case, reset the LockNode. You
can also replace a LockNode using the same process.
ü
The locking plan is open
ü
The 'Network' column is visible in the locking plan
1.
Find the LockNode WaveNet address. Position the mouse
cursor on the 'W' for the locking device and write down the
address
2.
Launch WaveNet Manager using 'Network' » 'WaveNet manager'
3.
Rightclick on the locking device
4.
If the LockNode is reset, select 'Replace with chip ID' and
maintain the ID entered
5.
If the LockNode is being replaced, enter the new chip ID
Manual
Door Monitoring Cylinder
28 / 72
SimonsVoss
2 | Initial operation