– Time switchover function: the cylinder engages automatically/
manually at a specific time. You can set its exact behaviour under
'Extended configuration.' If the time switchover function is
selected, bolt monitoring in the DoorMonitoring Cylinder must be
deactivated. The bolt position is only displayed correctly when the
time switchover function is deactivated
– Allow exceptions in time zone management (LSM Business and
higher): exceptions can be configured in time zone management
– No audible programming feedback signals: the locking cylinder
does not emit audible signals during the programming process
– Card interface: if a card reader is fitted to the cylinder, this is
where you can activate the function.
– Extended configuration: this is where you can configure time
switchover behaviour. These options are active as soon as a time
zone plan has been created
– Automatic engage: the locking device automatically engages
at the preset time
– Manual engage: the locking device automatically disengages
at the preset time. The locking device automatically engages
when actuated with a transponder
– Automatic disengage: the locking device automatically
disengages at the preset time
– Manual disengage: the locking device remains engaged at the
preset time. The locking device permanently disengages
when authorised
– Transponder always active: authorised ID media are able to
continue to lock the locking device while the locking device is
engaged
– Transponder only active if disengaged: authorised ID media
are not able to lock the locking device while the locking device
is engaged
– Software reset: the current status is reset in the software, to re
programme components which have not been programmed
completely, for example
Manual
Door Monitoring Cylinder
18 / 72
SimonsVoss
2 | Initial operation