Manual
Door Monitoring Cylinder
23 / 72
SimonsVoss
2 | Initial operation
– Magnetic field manipulation (fastening screw magnetic field too
extensive)
– Door has been forced open (door is opened despite locking)
– Reset: error messages must be reset manually
2.3.2 Network
The DoorMonitoring Cylinder allows the door status to be sent to LSM
within seconds. The information is transmitted via the SimonsVoss
WaveNet network
You will find detailed information on WaveNet installation in the
WaveNet manual on the SimonsVoss website
Installing hardware
The easiest way to install is using a CentralNode and an LN.I
– WNM.CN.UR.IO: CentralNode with USB connection to PC and
wireless interface for locking devices
– WNM.LN.I: thumbturn network cover for a TN4 Cylinder for direct
networking
ü
A database has been added
ü
The locking plan has been added
ü
A DoorMonitoring Cylinder has been added and programmed
ü
A transponder has been added and programmed with
authorisation for the DM Cylinder
ü
The CentralNode is connect to the PC with a USB cable
ü
The drivers for the CentralNode are installed
ü
WaveNet Manager is installed
ü
LSM is open
1.
Start WaveNet Manager (Network > WaveNet manager)
2.
Set the path for the WaveNetManager.exe and the output file
3.
Click on [Start]