2 Initial operation
Refer to the 'Digital Locking Cylinder and Half Cylinder – TN4' product
manual for general installation instructions. The manual describes
how the different cylinder versions are fitted.
This DM Cylinder manual that only deals with the special features of
the DM Cylinder. You must comply with the following steps when
installing and putting the DM Cylinder into operation:
– Replace the cover on the active side with the WaveNet network
cover
– Set up the DM Cylinder in LSM and programme the cylinder
– Install the DM Cylinder (see below)
– Put the network into operation locally using a PC or CommNode
Server (see FAQ entry 'WaveNet via CommNode Server: step by
step' in the Info Centre on the SimonsVoss website)
– Incorporate the cylinder (cylinder's LN.I) into the network; see
manual on WaveNet radio network. You should pay attention to
the signal strength when doing so; the level should not fall below
minus 70 dBm.
– Perform functions test with an authorised ID medium
2.1 Prerequisites
The DM Cylinder imposes the following minimum requirements for the
locking system and LSM:
– LSM 3.2 SP1 Basic, Business or Professional installed
– G2 or G2+G1 locking system
– The software LSM.Business with the modules LSM Online and
LSM Network xx (128 or Enterprise) is required for an online
connection (tasks and responses/events) to the DM Cylinder
The appropriate software modules and hardware components must
be installed to ensure door statuses in LSM can be further processed.
They define key events in the locking system and the action required.
The person responsible is thus informed by email if a fire door stays
open too long, for example.
– LSM Business
– LSM NETWORK xx
– LSM ONLINE
– WaveNet components (router and network covers)
Different functions are available, depending on the configuration:
Manual
Door Monitoring Cylinder