Manual
Door Monitoring Cylinder
19 / 72
SimonsVoss
2 | Initial operation
Monitoring
configuration
Illustration 9:
'Monitoring configuration' menu
NOTICE
The monitoring configuration has a direct influence on power
consumption in the cylinder.
The shorter the sampling interval is set for the fastening screw, the
greater power consumption is.
NOTICE
Changes to Door Monitoring configuration do not come into ef
fect until the cylinder has been programmed
– Sampling interval for the fastening screw: The sensor in the
fastening screw scans the magnetic field at adjustable intervals.
The shorter the sampling interval is set, the more complete
monitoring is, but also the greater power consumption is in the
cylinder. A practical compromise between effective door
monitoring and efficient power consumption would be 2 to 3
seconds. The function can also be switched off if opening of the
door is not to be logged. Setting: off
– 'Door open too long' event after: a signal is sent to LSM after the
preset time interval.
– Number of turns to lock: Depending on the lock, the bolt is fully
extended after one or a number of turns, thus locking the door
securely. You can set the number of turns in these menu items.