– Number of tasks
The number of activations totals up to 50,000.
The battery life depends on the fastening screw setting:
Sampling interval
Battery lifetime
0.2s
2.5 years
2s
4 years
3s
4.5 years
Table 4:
Sampling intervals and battery life
The battery life indicated serves as a guide. A battery warning is not
emitted when the aforementioned service life expires, but is based on
the measured battery capacity instead.
Battery warning levels
Warning Level 1
Warning Level 2
Freeze mode
8 short audible signals
before engaging
Eight short audible
signals 30 seconds
long with one second
pause each time
before engaging
6 audible signals (long
– pause – short)
Up to 15,000 access
events or up to 9
months on standby
Up to 50 access
events or up to 30
days
Battery change:
activate with battery
replacement
transponder
Table 5:
DM Cylinder battery warning levels
NOTICE
The cylinder's monitoring function is deactivated from Warning
Level 2. Changes to the cylinder status are not logged or trans
mitted.
Once Warning Level 2 has been emitted for the first time, the door
can be opened with a transponder around 50 times. After reaching
this number of opening operations or after about 4 weeks, the
cylinder automatically switches to freeze mode. In freeze mode, the
cylinder can only be replaced using a battery replacement
transponder in conjunction with an authorised transponder.
Freeze mode
The locking device switches to freeze mode if Battery Warning Levels
1 and 2 have not been observed or the locking system administrator
has not been informed of the battery warning. User transponders can
no longer activate the locking device to prevent the battery from being
fully discharged in this status.
Manual
Door Monitoring Cylinder
62 / 72
SimonsVoss
4 | Maintenance