2 | Initial operation
22. Import the tasks via File » Import from LSM Mobile » LSM Mobile
PC
Calibration tasks
There are seven designated steps for calibration
Steps to be carried out
Explanation
1. Locking device is programmed
and installed. Network is installed
Confirm that these tasks have
been completed. Network is not
absolutely necessary if the
cylinder is operated offline.
2. Open door and affix the
magnetic strip to the correct
position
Confirm after the magnetic plate
has been attached to the striking
plate opposite the fastening
screw. Affix the plate loosely first,
so that it can be moved if
necessary
3. Close door but do not lock
Carry out step and confirm. The
cylinder is read after confirmation
4. Open the door
Open the door. The cylinder is
read after confirmation
5. The locking device's bolt
position is initialised
Confirm. The cylinder is read and
initialised after confirmation
6. Close door and lock fully
Lock door. After confirmation, the
cylinder is scanned and the
number of cam rotations until the
door is securely locked is
detected. The user is asked if the
number of rotations is to be
entered
7. Unlock door without opening it
Unlock door. The cylinder is read
after confirmation
A trafficlightstyle indicator displays the status in addition to the
individual step:
– Yellow: step not yet implemented
– Green: step complete and positive feedback
– Red: indicates an error. Either the step has not been followed or
an error has been detected
NOTICE
Note on antipanic cylinder: There is no monitoring of bolt move
ment in the DM.AP2 Cylinder. This is why you need to carry out
Steps 1 to 4 when checking the DM.AP2 Cylinder. You can skip
the other steps. Press [OK & next] and ignore comments.