PVA-3000 Reference Manual
December 2, 2019
Sifos Technologies
Page
77
4.5.
Test Port Trigger Generation
The Test Port Event Trigger is used to enable synchronization of measurements across multiple test ports and multiple
instruments. This broadcast trigger capability was described earlier in Section 2.2.5. It is only available in PVA-3000,
PVA-3002, PSA-3000, and PSA-1200 instruments meaning it is not available in PSL-3000 and PSA-1200-PL
platforms.
Command
Port
Command Parameters
Query
Returned
Parameters
trigout
<
port
>
Produces an immediate broadcast Event Trigger.
4.6.
Test Port PHY Link Configuration
Test PHY Link Configuration commands and queries govern configurations of a 10/100/1000BaseT connection
between the Test PHY and a potential link partner. Configurations were addressed earlier in Section 2.2.1. Some of
these commands accept the broadcast configuration where
port
= 99,99.
Command
Port
Command Parameters
Query
Returned
Parameters
pva_reset
<
port
>
<
restore
>
Resets the Test PHY to known “power-on” state with auto-
negotiation fully enabled. Default is to reset all aspects of
Test PHY including Auto-Negotiation defaults and front-end
configurations. Accepts broadcast
port
= 99,99.
restore
: Retain present link rate (speed), duplex mode,
polarity, and gigabit timing mode following the reset.
pva_relink
<
port
>
Causes an immediate re-link to occur using any Auto-
Negotiation configurations previously specified and returns
link status. Accepts broadcast
port
= 99,99.
pva_speed
<
port
>
auto
|
1000
|
100
|
10
|
10+100
<
duplex auto
|
full
|
half
>
<
arm
>
LINKED |
UNLINKED |
ARMED
Configures Test PHY to advertise selected speed and link
duplex mode through either an immediate re-link (default)
or through a re-link to occur later. Note: Use command
pva_relink
to initiate the link change if “
arm
” is specified.
Use
pva_link_mon
to query link status. Returns
LINKED
if re-link is successful, returns
UNLINKED
if re-link fails,
and returns
ARMED
if ‘arm’ specified. Accepts broadcast
port
= 99,99 only in combination with
arm
argument.
auto
Configure speed to whatever rate is auto-negotiated
with link partner. Test PHY supports 10/100/1000BaseT.
(
wake-up default
)
1000
Configure Test PHY to advertise only 1000BaseT
available
100
Configure Test PHY to advertise only 100BaseTX
available
10
Configure Test PHY to advertise only 10BaseT available
10+100
Configure Test PHY to advertise both 100BaseTX
and 10BaseT available
duplex auto
Allow links to auto-negotiate for duplex mode
duplex full
Force link to full duplex only
duplex half
Force link to full duplex only
arm
Configure link speed and duplex mode but suppress
any re-link (auto-negotiation) until a later re-link operation
takes place. Enables use with port ‘99,99’.
?
AUTO
|
1000 | 100 | 10 |
10+100
+
AUTO
| FULL |
HALF | VARIOUS
Summary of Contents for PhyView PVA-3000
Page 22: ...PVA 3000 Reference Manual December 2 2019 Sifos Technologies Page 22 ...
Page 70: ...PVA 3000 Reference Manual December 2 2019 Sifos Technologies Page 70 ...
Page 108: ...PVA 3000 Reference Manual December 2 2019 Sifos Technologies Page 108 ...
Page 124: ...PVA 3000 Reference Manual December 2 2019 Sifos Technologies Page 124 ...