PVA-3000 Reference Manual
December 2, 2019
Sifos Technologies
Page
66
3.16.5.
Example 5: Measure Wideband Power Loss of Line Loss Impairment given 100BaseTX DUT
Test port 1,1 should be connected to a DUT that supports 100BaseTX operation.
Hint: If all pairs are impaired, then it won’t matter whether DUT links as MDI or MDI-X. Measure loss on either pair.
Menu
Task
Screen Shot
Port Select
Select the port to use for measurements
Click on
Port 1
in
Slot 1
on the
Slot Port Select
menu.
Port
Config
Configure the port to add the 100m Line
Impairment on Pair 3
Select the
Port Config
Tab.
Select
Impair All
under
100 Meter Cat5e
Click
Apply Selected Port Settings
Link
Config
Configure the Test Port speed, polarity and duplex
settings.
Select the
Link Config
Tab.
Select
100BaseTX
under
Link Speed
Click
Arm Configuration
Click
RE-LINK
Meters
Measure Power with line impairment switched in.
Select the
Meters
Tab
Select
100
under
Link Speed
Select
Power
under
Meter Type
Click
Measure
Port
Config
Configure the port to remove the 100m Line
Impairment from Pair 3
Select the
Port Config
Tab.
Select
No Impair
under
100 Meter Cat5e
Click
Apply Selected Port Settings
Meters
Measure Power with line impairment switched in.
Select the
Meters
Tab
Select
100
under
Link Speed
Select
Power
under
Meter Type
Click
Measure
Conclusion:
Wideband power loss of the Line
Loss impairment is
-
0.3 dB -
-
7.5 dB =
7.2 dB
.
Summary of Contents for PhyView PVA-3000
Page 22: ...PVA 3000 Reference Manual December 2 2019 Sifos Technologies Page 22 ...
Page 70: ...PVA 3000 Reference Manual December 2 2019 Sifos Technologies Page 70 ...
Page 108: ...PVA 3000 Reference Manual December 2 2019 Sifos Technologies Page 108 ...
Page 124: ...PVA 3000 Reference Manual December 2 2019 Sifos Technologies Page 124 ...