PVA-3000 Reference Manual
December 2, 2019
Sifos Technologies
Page
110
The
pva_caps
test evaluates
Link Stability
at each supported connection polarity (MDI/MDI-X) for each advertised
link rate (10/100/1000), duplex mode (half, full), and 1000BaseT timing mode (master, slave). The table below
describes each of the reported parameters from the
pva_caps
test.
Parameter
Value
Meaning
AUTO-NEG
NO
DUT does not support Auto-Negotiation
BASE
DUT supports Auto-Negotiation, but does not support Next Page Capability
EXTENDED
DUT supports Auto-Negotiation, including Next Page Capability
ACKS
N/A
Auto-Negotiation information not available
BASE
Link code word received
EXTENDED
Link code word received, Next Page Acknowledge received
NO
No acknowledgements received
1000BaseT
NO
DUT does not support 1000Base-T
HALF
DUT supports 1000Base-T Half Duplex only
FULL
DUT supports 1000Base-T Full Duplex only
HALF+FULL
DUT supports 1000Base-T Half Duplex and Full Duplex
N/A
Link not established
100BaseTX
NO
DUT does not support 100Base-TX
HALF
DUT supports 100Base-TX Half Duplex only
FULL
DUT supports 100Base-TX Full Duplex only
HALF+FULL
DUT supports 100Base-TX Half Duplex and Full Duplex
10BaseT
NO
DUT does not support 10Base-T
HALF
DUT supports 10Base-T Half Duplex only
FULL
DUT supports 10Base-T Full Duplex only
HALF+FULL
DUT supports 10Base-T Half Duplex and Full Duplex
100BaseT4
NO
DUT does not support 100Base-T4
YES
DUT does support 100Base-T4
Pause
NO
DUT does not support Pause operation
RESPOND
DUT capable of full duplex pause operation
XMIT
DUT desires asymmetric pause
XMIT
DUT desires asymmetric pause, capable of full duplex pause operation
Link_OK
FAULT
DUT has detected remote fault
YES
Link is OK
N/A
Could not be assessed
GIG_ERR
MASTER/SLAVE configuration fault detected
MDI / MDI-X
AUTO
DUT supports both MDI and MDI-X
MDI_ONLY
DUT support MDI only
MDI-X_ONLY
DUT support MDI-X only
NLP_Link
LINKED
DUT is able to link to non-auto-negotiating (10Base-T, Half-Duplex) partner
UNLINKED
DUT requires auto-negotiation in order to link
Rx_OK
NO
DUT Remote Receiver (1000Base-T) indicates Not OK
YES
DUT Remote Receiver (1000Base-T) indicates OK
N/A
Could not be assessed
– not applicable
Gig_Mode
AUTO
DUT supports both MASTER and SLAVE configuration
MASTER_ONLY
DUT supports both MASTER configuration only
SLAVE_ONLY
DUT supports both SLAVE configuration only
N/A
Could not be assessed
– not applicable
M-S Fault
NONE
Auto-Resolution of MASTER / SLAVE did not produce a Fault indication
FAULT
Auto-Resolution of MASTER / SLAVE produced a Fault indication
N/A
Could not be assessed
– not applicable
Mstr_Fault
NONE
Forced MASTER timing (link partner = SLAVE) did not produce Fault indicator
FAULT
Forced MASTER timing (link partner = SLAVE) produced a Fault indication
N/A
Could not be assessed
– not applicable
Slv_Fault
NONE
Forced SLAVE timing (link partner = MASTER) did not produce Fault indicator
FAULT
Forced SLAVE timing (link partner = MASTER) produced a Fault indication
N/A
Could not be assessed
– not applicable
Summary of Contents for PhyView PVA-3000
Page 22: ...PVA 3000 Reference Manual December 2 2019 Sifos Technologies Page 22 ...
Page 70: ...PVA 3000 Reference Manual December 2 2019 Sifos Technologies Page 70 ...
Page 108: ...PVA 3000 Reference Manual December 2 2019 Sifos Technologies Page 108 ...
Page 124: ...PVA 3000 Reference Manual December 2 2019 Sifos Technologies Page 124 ...