PVA-3000 Reference Manual
December 2, 2019
Sifos Technologies
Page
83
Command
Port
Command Parameters
Query
Returned
Parameters
pva_psd
<
port
>
<
trig off
|
ext
> <
pair
pairNo
> <
link 100
|
1000
> <
start
fstart
> <
stop
fstop
> <
avg
nAvgs
> <
timeout 10
|
100
>
stat
READY
+
List of 33 Frequency
& Amplitude (dB)
points
|
ARMED
|
MEASURING
|
TIMEOUT
|
LINK_DROP
|
UNLINKED
|
DISCONNECTED
Configures and performs a Power Spectral Distortion (PSD)
measurement using the calibration data previously acquired
for specified LAN pair, test port, and PVA instrument, and link
speed. Measurement may be either immediate or event
triggered. Configurations are retained in test port and in
PowerShell PSA software.
PSD measurements can be configured over a user selected
frequency range and will always return 33 discrete frequency
– amplitude (in dB) values.
trig off
Configures measurement to start immediately upon
stat
query. (
Test Port wake-up default
)
trig ext
Configures measurement to start upon receipt of the
first Event Trigger following a
stat
query.
pair
pairNo
Specifies LAN PAIR to measure. Range is 1 to 4
where Pair 1 is TIA blue pair, Pair 2 is TIA orange pair, Pair
3 is TIA green pair, and Pair 4 is the TIA brown pair. If link
is 100BaseT, only Pair 2 or 3 may be specified and
depending on pair number, link will be forced to MDI_X or
MDI respectively. (
This configuration is not maintained if
PSA Software is closed
.
PSA Software wake-up default
=
3.)
link 100
Specifies a measurement using 100BaseT. (
This
configuration is not maintained if PSA Software is closed.
PSA Software wake-up default.)
link 1000
Specifies a measurement using 1000BaseT.
(This
configuration is not maintained if PSA Software is closed. )
start
fstart
Specifies start frequency for frequency response
analysis. Range is 0.02 MHz to 80 MHz.
(This
configuration is not maintained if PSA Software is closed.
PSA Software wake-up default = 1 MHz.)
stop
fstop
Specifies end frequency for frequency response
analysis. Range is 0.2 MHz to 100 MHz.
(This
configuration is not maintained if PSA Software is closed.
PSA Software wake-up default = 100 MHz.)
avg
nAvgs
Specifies the number of raw measurements to
average into each channel response coefficient. Range is
1 to 64. If
fstart
is less than 1 MHz,
nAvgs
must be between
48 and 64. (
Test Port wake-up default = 10.
)
timeout 10
specifies that an Event Triggered measurement
should time out if no trigger is received within 10 seconds
following
stat
query. (
Test Port wake-up default
)
timeout 100
specifies that an Event Triggered measurement
should time out if no trigger is received within 100 seconds
following
stat
query.
?
Trigger_Mode (
off
|
ext
)
+
pairNo
+
Link_Speed (
100
|
1000
)
+
fstart
+
fstop
+
nAvgs
+
Timeout
10
|
100
Summary of Contents for PhyView PVA-3000
Page 22: ...PVA 3000 Reference Manual December 2 2019 Sifos Technologies Page 22 ...
Page 70: ...PVA 3000 Reference Manual December 2 2019 Sifos Technologies Page 70 ...
Page 108: ...PVA 3000 Reference Manual December 2 2019 Sifos Technologies Page 108 ...
Page 124: ...PVA 3000 Reference Manual December 2 2019 Sifos Technologies Page 124 ...