
Setup with the integrated HMI
7.5.2 Quick setup level, space, distance
Material type
Used to optimize the device function depending on the type of material and vessel or
application:
Setting
Selection
Selection
Vessel
STRGE
Process vessel with agitation
PRCSS
Wet well
WTWLL
Outside of Plastic Tank
PLSTC
Level of open liquid
OPEN
Demonstration
LIQUID
DEMO MODE
Silo
SILO
Buffer, surge bin
BIN
Heap, pile
MATERIAL TYPE
SOLID
OPEN
Heap profile
Unit
UNITS:
Sets the measuring unit used (default setting in brackets):
• Meter "
m
"
(3 decimal places)
• Centimeter "
cm
"
(1 decimal place)
• Feet "
ft
"
(3 decimal places)
• Inches "
in
"
(2 decimal places)
Lower calibration point
LOWER CAL PT:
Sets the distance from the transmitter reference point to the lower calibration point:
usually corresponds to the zero point of the process.
Upper calibration point
UPPER CAL PT:
Sets the distance from the transmitter reference point to the upper calibration point:
usually corresponds to the full level.
Confirm
CONFIRM:
Accepts the settings as the last step in the wizard.
SITRANS LR150
Operating Instructions, 08/2020,
A5E50352155
37