Various Interface Signals (A2)
1.6 NC services
Turning, Milling, Nibbling
32
Function Manual, 11/2012, 6FC5397-1CP10-5BA0
1.6.1.2
PI service ASUB
Initialization
With the ASUB PI service, it is possible to assign the interrupt numbers 1 and 2 fixed
program names from the PLC. Prerequisite for this is the existence of the PLCASUP1_SPF
or PLCASUP2_SPF programs in the CMA directory.
PI index
Function
VB1200 0001 = 1
Assignment of Interrupt 1 to the CMA_DIR/PLCASUP1_SPF program.
The interrupt has Priority 1.
VB1200 0001 = 2
Assignment of Interrupt 2 to the CMA_DIR/PLCASUP2_SPF program.
The interrupt has Priority 2.
The following must be taken into account during the initialization:
●
The PI service ASUB requires executing only once after a restart and is then retained.
●
An initialization may only be performed when the channel is not active.
●
If a "Ramp-up" program event has been configured, the initialization may only be started
after the end of the program event.
Relevant interface signals
Address
Name
Valid values
V1200 0000.0
Start
0/1
V1200 0000.1
Write variable
0
V1200 0000.2
PI service
1
Job
V1200 0001
PI index
1,2
V1200 2000.0
Request completed
0/1
Result
V1200 2000.1
Error in job
0/1