Parameter list
8.2 Parameter list
SINAMICS V20 Converter
324
Operating Instructions, 10/2019, A5E34559884-012
Parameter
Function
Range
Factory
default
Can be
changed
Scaling
Data
set
Data
type
Acc.
Level
P2946
Wobble signal ampli-
tude [%]
0.000 - 0.200
0.000
T
-
-
Float 2
Sets the value for the amplitude of the wobble-signal as a proportion of the present ramp function genera-
tor (RFG) output.
The value of P2946 is multiplied by the output value of the RFG then added to RFG output.
For example, if the RFG output is 10 Hz, and P2946 has a value of 0.100, the wobble signal amplitude will
be 0.100 * 10 = 1 Hz. This means that the RFG output will therefore wobble between 9 Hz and 11 Hz.
P2947
Wobble signal decre-
ment step
0.000 - 1.000
0.000
T
-
-
Float 2
Sets the value for decrement step at the end of the positive signal period. The amplitude of the step is
dependent upon the signal amplitude as follows:
Amplitude of signal decrement step = P2947 * P2946
P2948
Wobble signal incre-
ment step
0.000 - 1.000
0.000
T
-
-
Float 2
Sets the value for the increment step at the end of the negative signal period. The amplitude of the incre-
ment step is dependent upon the signal amplitude as follows:
Amplitude of signal increment step = P2948 * P2946
P2949
Wobble signal pulse
width [%]
0 - 100
50
T
-
-
U16
2
Sets the relative widths of the rising and falling pulses.
The value in P2949 sets the proportion of the wobble
period (determined by P2945) allocated to the rising pulse, the remainder of the time is allocation to the falling pulse.
A value of 60% in P2949 means that 60% of the wobble period the wobble output will be rising. For the
remaining 40% of the wobble period the wobble output will be falling.
r2955
CO: Wobble signal
output [%]
-
-
-
-
-
Float 2
Displays the output of the wobble function.
r3113.0...15 CO/BO: Fault bit array
-
-
-
-
-
U16
1
Gives information about actual fault.
Bit
Signal name
1 signal
0 signal
00
Converter error
Yes
No
01
Power line failure
Yes
No
02
Intermediate circuit power voltage
Yes
No
03
Error power electronics
Yes
No
04
Converter overtemperature
Yes
No
05
Earth leakage
Yes
No
06
Motor overload
Yes
No
07
Bus fault
Yes
No
09
Reserved
Yes
No
10
Fault internal communication
Yes
No
11
Motor current limit
Yes
No
12
Supply failure
Yes
No
13
Reserved
Yes
No
14
Reserved
Yes
No
15
Other error
Yes
No