Subracks
2-8
Hardware - SIMADYN D
Edition 04.2011
2.1.7 Technical data
AC power supply
according to DIN IEC 38
Input voltage Vin
230 V (+ 10% / - 15%)
Input frequency
47.5 ... 62.5 Hz
Non-periodic overvoltages
according to DIN VDE160, A5.3.1.1.2
Voltage 460
V
Duration 1.3
ms
Recovery time, min
0.1 s
Events per hour
max. 10
Brief voltage dips
according to DIN VDE 0160, A5.3.1.1.3
Voltage 0
Duration 5
ms
Recovery time, min
0.1 s
Events per hour
max. 10
Output voltage 5 V
+5.1 V +/- 0.1 V
Output current
1.5 to
7 A
Ripple
< 50 mVpp
Commutating spikes
< 5% (of 5V)
Base load
1.5 A
when a CPU module is inserted
Overvoltage protection
with suppressor diode
to protect the modules
Stabilization time
< 80 ms after Vin= 230 V;
<1 ms
after load step (0.5 ->1)*Irated
Output v15 V
+15 V +/- 0.3 V
Output current
0 to
0.7 A
Ripple
< 150 mVpp
Base load
Guaranteed by an inserted module
which requires this voltage
Input voltages
Output voltages
Aotewell Ltd
www.aotewell.com
Industry Automation
HongKong|UK|China
+86-755-8660-6182