Application notes
Version 8 dated 15.03.00
162
Siemens Information and Communication Products
8.2.5.2
Start Procomm Plus
(START - programs - Procomm - Procomm Plus)
To activate configuration file:
Activate "M20_start" by double-clicking in the data - pulldown menu.
M20T connected and ON (see chapter 3.3.1)
This automatically configures the system to connect to the M20T via COM1.
The script "Start" automatically is activated and a sequence of commands is executed giving information about the settings
of the M20.
Enter the PIN code in the pop up window.
Once the M20T is booked into the net, -- +creg:1 - network information is displayed
M20T Ready.
NOTE
: If the script is unable to process a command, there is a 15 second internal timeout after which the next command
is automatically sent to the M20.
NOTE
: If the script does not operate correctly it can be stopped/exited and restarted with the Button .
The Procomm Plus scripts for Data, Voice and SMS incoming and outgoing can be activated from the script window.
Using the script control button
a script can be started and stopped.
8.2.6
Setting parameters
8.2.6.1
Enter PIN1
8.2.6.2
Enter PUK1
8.2.6.3
Change PIN1
at+cpin?
Ask which PIN is required
+CPIN: SIM PIN
SIM PIN is needed
OK
at^spic
Display PIN counter
^SPIC: 3
3 attempts still available
OK
at+cpin="xxxx"
Enter PIN
OK
at+cpin?
+CPIN: SIM PUK
SIM PUK is required
OK
at^spic
^SPIC: 10
10 attempts still available for SIM PUK
OK
at+cpin="xxxxxxxx","xxxx"
Enter PUK and new PIN
OK
at+cpin?
+CPIN: READY
SIM is ready
OK