Application notes
Version 8 dated 15.03.00
172
Siemens Information and Communication Products
NOTE
:2) If you are unable to receive Fax with the M20 but sending works then check with your provider if T62 fax pro-
tocol is enabled for your SIM card
Before starting WINFAX:
In this example the M20 is connected via the serial connection COM1, it works the same with COM2.
1) Check if Winfax controller is active (small fax icon in the bottom right-hand corner of the screen). If this is the case,
click the icon with the right mouse button and close all Winfax related programs and drivers. This enables the terminal
program to connect with the M20 via the serial COM port.
2) Open the terminal program and log the M20 into the net. Once the M20 is logged in, you must close/disconnect the
Terminal program from the COM port.
3) Start Winfax Pro
4) Use the below mentioned settings for sending and receiving a fax.
WINFAXPRO settings:
pulldown menu of WinFax:
Menu - path
Function
Setting
Settings-Modem
Modem
Standard 9600
Port
Com1
Settings-Modem-Properties-General
Communication Port
Com1
Initialize with
19200
Fax/Modem - Type
Class 1
Settings-Modem-Properties-Fax
Modem connection
Mobile transmission
Transfer rate: max.
9600
Transfer rate: min.
2400
Initialisation seq,1)
AT&F&C1&D2S7=55
Initialisation seq,2)
AT+ifc=2,2
Protocol HW
ON
Reset command
ATZ
ECM sending
ON
ECM receiving
ON
2D-Compression
OFF
Settings-Call reception
Automatic Reception
ON
Accept call after x rings
X=1