3.3
VMS4200-x / 5200-x MID without object detection
The VMS4200-x / 5200-x MID multi-dimensional measurement system measures cubic
and irregularly shaped objects that are linearly moved past the measuring station on
single cross belt sorters or double belt sorters.
3.3.1
Measurement principle
Fig. 11: Measurement principle
Legend
1
Measurement site
2
Scanning line
•
The objects are always measured
separately
.
•
Only
one object
can be in the
measuring range
at any given time.
NOTE!
The objects must be located fully on the cross-belt conveyor element.
The measuring field is limited to the cross-belt conveyor element.
The VMS4200-x / 5200-x MID will otherwise deliver invalid measurement results.
In the case of the VMS5200-x MID, these are designated as NON-LFT.