Parameter
Value
Factory setting
Qa 0 V teach-in (auto)
OD2000-
030
:
-5.04 mm ... +5.75 mm
OD2000-
050
:
-10.10 mm ... +11.50 mm
OD2000-
245
:
-176.75 mm ... +189.00 mm
OD2000-
350
:
-252.50 mm ... +271.00 mm
OD2000-
700
:
-505.00 mm ... +550.00 mm
OD2000-
030
: -5.00 mm
OD2000-
050
: -10.00 mm
OD2000-
245
: -175.00 mm
OD2000-
350
: -250.00 mm
OD2000-
700
: -500.00 mm
Qa 0 V teach-in (manual)
Qa 10 V teach-in (auto)
OD2000-
030
: +5.00 mm
OD2000-
050
: +10.00 mm
OD2000-
245
: +175.00 mm
OD2000-
350
: +250.00 mm
OD2000-
700
: +500.00 mm
Qa 10 V teach-in (manual)
7.4.4.4
Q2 output mode
Digital output functions can also be set instead of analog output modes. The operation
and setting options are identical to output Q1,
.
Additionally, at Q2 the
Q2 Q2=Q1 not
function is not available (inversion of Q1). With this
function, the inverted switching signal of Q1 is output via Q2. For example, if the High
signal is output at Q1, Low is output via Q2.
Setting digital output
>
Q2 / Qa Output
>
>
Q2 Mode
>
> Select output mode (switching) >
7.4.5
IN input
To use the functions at the
IN Input
, the input must be active (any setting except
Off
). The
Off
setting deactivates the input and, therefore, all functions.
NOTE
Deactivating the input is possible only via the display, SOPAS ET, or IO-Link, but not via
the input itself.
The behavior of the input can be selected as normally open contact (
High-active
, factory
setting) or normally closed contact (
Low-active
). When
Sender off
is used, the logic also
determines whether the creation of a signal at the input causes the sender to switch off
(factory setting) or on.
7.4.5.1
IN Function
Functions
•
Switch the sender on and off at defined times.
•
Activate device functions.
Sender off
: The sender is switched off for the duration of the applied signal.
Setting IN function
>
In1 Input
>
>
IN Function
>
> Select option >
Parameter
Value
Factory setting
IN Function
Off
Hold
Zero point teach-in
Sender off
Sender off
OPERATION
7
8026231//2021-11-17 | SICK
O P E R A T I N G I N S T R U C T I O N S | OD2000
41