Teaching analog value
Set the analog value to the current distance at the time the button is pressed,
Teachable parameters
•
Qa 4 mA teach-in (auto)
•
Qa 20 mA teach-in (auto)
•
Qa 0 V teach-in (auto)
•
Qa 10 V teach-in (auto)
To teach in an analog value, the device must be able to measure. The distance to the
object must not change during teach-in. The object must be in the measuring range.
Setting analog value manually
Set the analog value manually,
see "Adjust the value", page 23
Adjustable parameters
•
Qa 4 mA teach-in (manual)
•
Qa 20 mA teach-in (manual)
•
Qa 0 V teach-in (manual)
•
Qa 10 V teach-in (manual)
7.4.4.2
Analog 4-20 mA output mode
Output Q2 is an analog current output. The measured value is output in the form of a
linearly proportional current value.
Selecting output mode and setting parameters
>
Q2 / Qa Output
>
>
Q2 Mode
>
>
Qa Analog 4...20 mA
>
>
Q2 / Qa Output
>
> Parameter >
> Teach-in or set value>
Parameter
Value
Factory setting
Qa 4 mA teach-in (auto)
OD2000-
030
:
-5.04 mm ... +5.75 mm
OD2000-
050
:
-10.10 mm ... +11.50 mm
OD2000-
245
:
-176.75 mm ... +189.00 mm
OD2000-
350
:
-252.50 mm ... +271.00 mm
OD2000-
700
:
-505.00 mm ... +550.00 mm
OD2000-
030
: -5.00 mm
OD2000-
050
: -10.00 mm
OD2000-
245
: -175.00 mm
OD2000-
350
: -250.00 mm
OD2000-
700
: -500.00 mm
Qa 4 mA teach-in (manual)
Qa 20 mA teach-in (auto)
OD2000-
030
: +5.00 mm
OD2000-
050
: +10.00 mm
OD2000-
245
: +175.00 mm
OD2000-
350
: +250.00 mm
OD2000-
700
: +500.00 mm
Qa 20 mA teach-in (manual)
7.4.4.3
Analog 0-10 V output mode
Output Q2 is an analog voltage output. The measured value is output in the form of a
linearly proportional voltage value.
Selecting output mode and setting parameters
>
Q2 / Qa Output
>
>
Q2 Mode
>
>
Qa Analog 0…10 V
>
>
Q2 / Qa Output
>
> Parameter >
> Teach-in or set value >
7
OPERATION
40
O P E R A T I N G I N S T R U C T I O N S | OD2000
8026231//2021-11-17 | SICK
Subject to change without notice