Figure 18: Edge height jump: Duration of the change in measured value is
shorter
than the time
span of the cycle offset.
1
Cycle offset: 4, without measured value filter
2
Fixed cycle time, e.g. 1 ms
3
Signal diagram for real distance
4
Max. limit value for edge height change (mm)
5
Min. limit value for edge height change (mm)
6
Change in measured value, from large to small distance
7
Change in measured value, from small to large distance
8
Signal diagram for digital output
9
Parameter
Jump direction
>
Both
ß
Parameter
Jump direction
>
Negative
à
Parameter
Jump direction
>
Positive
7.4.3.8
Off output mode
If the
Off
output mode is activated, the Q1 output has no function and is deactivated.
7.4.4
Q2/Qa output
The Q2/Qa output can be configured either as an analog output or as a digital output.
If an output mode is selected, the required settings can be taught in or set manually.
Depending on the selected output mode, different parameters are available.
7.4.4.1
Setting analog value
An analog value can be taught-in or set manually. Do not teach in the same distance
value for the near-sensor and far-sensor distances.