Selecting output mode and setting parameters
>
Q1 Output
>
>
Q1 Mode
>
>
Q1 Alarm
>
>
Q1 Output
>
> Parameter >
> Select option >
Parameter
Value
Factory settings
Q1 Switch point logic
High-active
Low-active
High-active
7.4.3.6
Signal level warning output mode
If the signal level falls below a threshold, a warning is issued via digital outputs Q1
and Q2. The signal threshold can be taught-in or set manually as a numerical value.
The signal level is a sensor-specific, unitless value. Adjusting the signal level using
application-specific test measurements is recommended.
Selecting output mode and setting parameters
>
Q1 Output
>
>
Q1 Mode
>
>
Q1 Signal level warning
>
>
Q1 Output
>
> Parameter >
> Select option, teach-in or set value >
Parameter
Value
Factory settings
Q1 Signal threshold (auto)
0 ... 5,000
1700
Q1 Signal threshold (manual)
Q1 Switch point logic
High-active
Low-active
High-active
Q1 Timer mode
Off
Switch-on delay
Switch-off delay
Switch-on/off delay
Pulse (one shot)
Off
Q1 Timer setup
1 ms ... 30,000 ms
1 ms
7.4.3.7
Edge height jump output mode
If a measured value jump occurs between two measured values, a signal is output. A
typical application is copy or scale counting in print applications. The device takes on
the complex evaluation tasks carried out by the control system.
Settings for using the function
•
•
Fixed
(recommended)
NOTE
In
Auto
mode, fluctuating reflectance values of the object surface can change the
cycle time of the device. This means that reliable detection is not guaranteed at
high detection speeds or with small structures.
•
(if required)
•
(if required)
•
(if required)
Selecting output mode and setting parameters
>
Q1 Output
>
>
Q1 Mode
>
>
Q1 Edge height jump
>
>
Q1 Output
>
> Parameter >
> Select option, teach-in or set value >
7
OPERATION
36